<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Occupational Hygiene Engineering</title>
<title_fa>مجله مهندسي بهداشت حرفه اي</title_fa>
<short_title>johe</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://johe.umsha.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2383-336x</journal_id_issn>
<journal_id_issn_online>2383-3378</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.53208/johe</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1393</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>1</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>ارائه طرح بهینه سامانه کشف، اعلام و اطفاء حریق خودکار در آزمایشگاه‎های یک واحد آموزش دانشگاهی</title_fa>
	<title>Planning an Automatic Fire Detection, Alarm, and Extinguishing System for Research Laboratories</title>
	<subject_fa>ایمنی</subject_fa>
	<subject>Safety</subject>
	<content_type_fa>مقاله پژوهشي</content_type_fa>
	<content_type>Research Article</content_type>
	<abstract_fa>&lt;p&gt;&amp;nbsp;&lt;strong&gt; زمینه و هدف: &lt;/strong&gt;آزمایشگاه&#8204;های مراکز آموزشی نظیر دانشگاه&#8204;ها به دلیل دارا بودن انواع گوناگونی از مواد و تجهیزات دارای ریسک بالایی به لحاظ حریق می&#8204;باشند. هدف مطالعه حاضر ارائه طرح بهبود ایمنی حریق در آزمایشگاه &amp;lrm; های یک واحد آموزش دانشگاهی مبتنی بر طراحی سامانه کشف، اعلام و اطفاء حریق خودکار بوده است.&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;strong&gt; روش بررسی: &lt;/strong&gt;در مطالعه توصیفی- تحلیلی کاربردی حاضر ارزیابی ریسک حریق با استفاده از روش ارزیابی ریسک ارتش ایالات&#8204;متحده آمریکا ( MIL-STD-882 ) صورت گرفت. برای کلیه آزمایشگاه&#8204;ها سامانه کشف و اعلام حریق طراحی گردید و سپس یک سامانه اطفاء حریق ثابت خودکار طراحی گردید.&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;strong&gt; یافته&#8204;ها: &lt;/strong&gt;بر اساس نتایج این مطالعه آزمایشگاه&#8204;های شیمی آب و فاضلاب (25/81) و عوامل فیزیکی (5/62) به ترتیب بیشترین و کمترین درصد ریسک حریق را دارا بودند. بر طبق محاسبات و با در نظر گرفتن عوامل فنی، سامانه کشف مبتنی بر کاشف&#8204;های دودی فتوالکتریک و حرارتی نرخ افزایشی و سامانه خاموش&#8204;کننده بر مبنای CO2 در این مکان&#8204;ها طراحی گردید.&lt;/p&gt;

&lt;p&gt;&amp;nbsp;&lt;strong&gt; نتیجه&#8204;گیری: &lt;/strong&gt;با توجه به بالا بودن ریسک&#8204; حریق در آزمایشگاه&#8204;ها و ویژگی&#8204;های خاص این واحدها بهترین راهکار کنترلی حفاظت در برابر حریق طراحی و به&#8204;کارگیری سامانه کشف، اعلام و اطفا، حریق خودکار بود که مناسب&#8204;ترین روش اطفاء حریق برای چنین مکان&#8204;هایی سامانه مبتنی بر ماده خاموش&#8204;کننده دی&#8204;اکسید کربن ( CO2 ) است.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&amp;nbsp; &lt;strong&gt;Background &amp; Objectives: &lt;/strong&gt;Educational and research laboratories in universities have a high risk of fire, because they have a variety of materials and equipment. The aim of this study was to provide a technical plan for safety improvement in educational and research laboratories of a university based on the design of automatic detection, alarm, and extinguishing systems .&lt;/p&gt;

&lt;p&gt;&amp;nbsp; &lt;strong&gt;Methods &lt;/strong&gt;: In this study, fire risk assessment was performed based on the standard of Military Risk Assessment method (MIL-STD-882). For all laboratories, detection and fire alarm systems and optimal fixed fire extinguishing systems were designed.&lt;/p&gt;

&lt;p&gt;&amp;nbsp; &lt;strong&gt;Results &lt;/strong&gt;: Maximum and minimum risks of fire were in chemical water and wastewater (81.2%) and physical agents (62.5%) laboratories, respectively. For studied laboratories, we designed fire detection systems based on heat and smoke detectors. Also in these places, fire-extinguishing systems based on CO&lt;sub&gt;2&lt;/sub&gt; were designed .&lt;/p&gt;

&lt;p&gt;&amp;nbsp; &lt;strong&gt;Conclusion &lt;/strong&gt;: Due to high risk of fire in studied laboratories, the best control method for fire prevention and protection based on special features of these laboratories is using automatic detection, warning and fire extinguishing systems using CO&lt;sub&gt;2&lt;/sub&gt; .&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;</abstract>
	<keyword_fa>ریسک حریق, کشف حریق, اطفاء حریق, آزمایشگاه آموزشی</keyword_fa>
	<keyword>Fire detection, Fire extinguishing, Research laboratories</keyword>
	<start_page>57</start_page>
	<end_page>65</end_page>
	<web_url>http://johe.umsha.ac.ir/browse.php?a_code=A-10-1-7&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Rostam</first_name>
	<middle_name></middle_name>
	<last_name> Golmohamadi</last_name>
	<suffix></suffix>
	<first_name_fa>رستم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>گلمحمدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006792</code>
	<orcid>10031947532846006792</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>Iraj </first_name>
	<middle_name></middle_name>
	<last_name>Mohamadfam</last_name>
	<suffix></suffix>
	<first_name_fa>ایرج</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محمدفام</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006793</code>
	<orcid>10031947532846006793</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>Masoud </first_name>
	<middle_name></middle_name>
	<last_name>Shafiee Motlagh</last_name>
	<suffix></suffix>
	<first_name_fa>مسعود</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>شفیعی مطلق</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>HSE.masoudshafii@yahoo.com</email>
	<code>10031947532846006794</code>
	<orcid>10031947532846006794</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>Ebrahim </first_name>
	<middle_name></middle_name>
	<last_name>Darvishi</last_name>
	<suffix></suffix>
	<first_name_fa>ابراهیم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>درویشی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006795</code>
	<orcid>10031947532846006795</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی کردستان</affiliation_fa>
	 </author>


	<author>
	<first_name>Akram </first_name>
	<middle_name></middle_name>
	<last_name>Mortezaie</last_name>
	<suffix></suffix>
	<first_name_fa>اکرم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مرتضایی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006796</code>
	<orcid>10031947532846006796</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی همدان</affiliation_fa>
	 </author>


	<author>
	<first_name>Faeze </first_name>
	<middle_name></middle_name>
	<last_name>Azizian</last_name>
	<suffix></suffix>
	<first_name_fa>فائزه</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عزیزیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006797</code>
	<orcid>10031947532846006797</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی همدان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
