<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Occupational Hygiene Engineering</title>
<title_fa>مجله مهندسي بهداشت حرفه اي</title_fa>
<short_title>johe</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://johe.umsha.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2383-336x</journal_id_issn>
<journal_id_issn_online>2383-3378</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>10.53208/johe</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>8888</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1395</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2016</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<volume>3</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>بررسی اثرات توام گرما و روشنایی بر روی زمان واکنش دانشجویان در شرایط آزمایشگاهی</title_fa>
	<title> Investigating the combined effects of heat and lighting on students reaction time in laboratory condition</title>
	<subject_fa>عوامل فیزیکی</subject_fa>
	<subject>Physical agents</subject>
	<content_type_fa>مقاله پژوهشي</content_type_fa>
	<content_type>Research Article</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;مقدمه:&lt;/strong&gt; در بسیاری از محیط های کاری مواجهه با گرما و روشنایی به صورت توام وجود دارد این مطالعه با هدف بررسی تاثیر توام گرما و روشنایی بر روی زمان واکنش انجام شد&lt;strong&gt;.&lt;/strong&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; این مطالعه نیمه تجربی در سال 1394بر روی 33 نفر از دانشجویان (16دختر و17پسر) با میانگین سنی 22/1 در اتاقک تنش حرارتی انجام شد. پارامتر زمان واکنش با استفاده از دستگاه سنجش زمان واکنش پس از 1/5 ساعت مواجهه توام با سطوح مختلف گرما (دماهای خشک &lt;span dir=&quot;LTR&quot;&gt;c&lt;/span&gt;&amp;deg;22 و&amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;c&lt;/span&gt;&amp;deg;37 ) و سطوح مختلف روشنایی (500 ،200 و 1500 لوکس) اندازه گیری شد. داده ها با آزمون&amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;ANOVA&lt;/span&gt; نرم افزار 20-SPSS&amp;nbsp;مورد تحلیل قرار گرفتند.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;یافته ها:&lt;/strong&gt; یافته ها نشان داد که افزایش توام گرما و شدت روشنایی پس از گذشت 1/5 ساعت مواجهه، باعث اختلاف معنی دار و افزایش میانگین زمانهای واکنش ساده، تشخیصی،انتخابی دو رنگ و انتخابی دو صدا شده است (0/05˂&lt;span dir=&quot;LTR&quot;&gt;P&lt;/span&gt;). نمره زمان واکنش هنگام مواجهه با دمای&amp;nbsp;&lt;span dir=&quot;LTR&quot; style=&quot;color: rgb(51, 51, 51); font-family: Tahoma, Arial, Verdana; font-size: 13px; text-align: justify; background-color: rgb(255, 255, 255);&quot;&gt;C&lt;/span&gt;&lt;span style=&quot;color: rgb(51, 51, 51); font-family: Tahoma, Arial, Verdana; font-size: 13px; text-align: justify; background-color: rgb(255, 255, 255);&quot;&gt;&amp;deg;37&lt;/span&gt; و شدت روشنایی 1500 لوکس دارای بیشترین مقدار و هنگام مواجهه با دمای&amp;nbsp;&lt;span dir=&quot;LTR&quot;&gt;C&lt;/span&gt;&amp;deg;22 و شدت روشنایی 1500 لوکس کمترین مقدار بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot; style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;نتیجه گیری:&lt;/strong&gt; نتایج این مطالعه نشان داد که افزایش توام گرما و شدت روشنایی از طریق افزایش زمان واکنش و خطای زمان واکنش افراد در هنگام انجام فعالیتهای شناختی می تواند باعث کاهش عملکرد شناختی افراد شود. بنابراین در پست های کاری که نیازمند عکس العمل سریع هستند، بهینه سازی شرایط گرما و روشنایی به منظور کاهش زمان واکنش الزامیست.&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Introduction&lt;/strong&gt;: In many workplaces there is exposure to heat and light simultaneously. This study investigated the combined effect of heat and lighting on some cognitive performance, i.e. reaction time.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Methodology&lt;/strong&gt;: the present semi-experimental study was conducted 2015 on 33 healthy students (16 girls and 17 boys) with a mean age of 22.1 in the thermal stress chamber. The reaction time parameter by the reaction time measurement device, after exposure to different heat surfaces (dry temperatures 22 &amp;deg;C and 37 &amp;deg;C) and lighting surfaces (200, 500 and 1500 lux). Data were analyzed using ANOVA test in SPSS-20.&lt;/p&gt;

&lt;p style=&quot;text-align: justify;&quot;&gt;&lt;strong&gt;Results&lt;/strong&gt;: The results showed that the average simple, diagnostic, two-color selective, two-sound selective reaction times and reaction time error increased after combined exposure to heat and lighting and showed a significant difference (P&lt;0.05). The maximum score of reaction time belong to temperature of 37 c&amp;deg; and lighting of 1500 lux, the minimum score of reaction time belong to temperature of 22 &amp;deg;c and lighting of 1500 lux.&lt;/p&gt;
</abstract>
	<keyword_fa>کلمات کلیدی: گرما, روشنایی, اثرات توام, زمان واکنش, عملکرد شناختی</keyword_fa>
	<keyword>Keywords: Heat, Combined Effect, Lighting, Reaction Time</keyword>
	<start_page>40</start_page>
	<end_page>46</end_page>
	<web_url>http://johe.umsha.ac.ir/browse.php?a_code=A-10-288-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Zohre</first_name>
	<middle_name></middle_name>
	<last_name>Mohebian</last_name>
	<suffix></suffix>
	<first_name_fa>زهره</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>محبیان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>zohre.mohebian@yahoo.com</email>
	<code>10031947532846006645</code>
	<orcid>10031947532846006645</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Occupational Health Engineering, Faculty of Health, Iranshahr University of Medical Sciences, Iranshahr, Iran.</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت حرفه ای، دانشکده علوم پزشکی ایرانشهر ،ایران.</affiliation_fa>
	 </author>


	<author>
	<first_name>Younes</first_name>
	<middle_name></middle_name>
	<last_name>Mehrifar</last_name>
	<suffix></suffix>
	<first_name_fa>یونس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>مهری فر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ymehrifar@yahoo.com</email>
	<code>10031947532846006646</code>
	<orcid>10031947532846006646</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Occupational Health Engineering, School of Health</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت حرفه ای، دانشکده بهداشت</affiliation_fa>
	 </author>


	<author>
	<first_name>Habibollah</first_name>
	<middle_name></middle_name>
	<last_name>Dehghan</last_name>
	<suffix></suffix>
	<first_name_fa>حبیب اله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>دهقان</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>ha_dehghan@hlth.mui.ac.ir</email>
	<code>10031947532846006647</code>
	<orcid>10031947532846006647</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Department of Occupational Health Engineering, School of Health</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت حرفه ای، دانشکده بهداشت</affiliation_fa>
	 </author>


	<author>
	<first_name>Ehsanollah</first_name>
	<middle_name></middle_name>
	<last_name>Habibi</last_name>
	<suffix></suffix>
	<first_name_fa>احسان اله</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>حبیبی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>habibi@hlth.mui.ac.ir</email>
	<code>10031947532846006648</code>
	<orcid>10031947532846006648</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Department of Occupational Health Engineering, School of Health</affiliation>
	<affiliation_fa>گروه مهندسی بهداشت حرفه ای، دانشکده بهداشت</affiliation_fa>
	 </author>


	<author>
	<first_name>Ghasem</first_name>
	<middle_name></middle_name>
	<last_name>Yadegarfar</last_name>
	<suffix></suffix>
	<first_name_fa>قاسم</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>یادگارفر</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code>10031947532846006649</code>
	<orcid>10031947532846006649</orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa>گروه آمار زیستی و اپیدمیولوژی</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
